What was found
PHX - DURING SCHEDULED C6 INSPECTION, FOUND L1 DOOR FORWARD GIRT BAR ATTACH FITTING CORRODED. FABRICATED NEW ATTACH FITTING IAW SRM 51-10-02. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING SCHEDULED C6 INSPECTION, FOUND L1 DOOR FORWARD GIRT BAR ATTACH FITTING CORRODED. FABRICATED NEW ATTACH FITTING IAW SRM 51-10-02. (M)