What was found
PHX - DURING SCHEDULED C1 INSPECTION, FOUND BAG PIT FLOORBOARD SUPPORT STRUCTURE CORRODED FROM STA 1320 TO STA 1420 BETWEEN STR 28 AND STR 29. FABRICATED AND INSTALLED DOUBLER AND FILLER PER SRM 51 70 11 AND SRM 51 40 02. (X)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING SCHEDULED C1 INSPECTION, FOUND BAG PIT FLOORBOARD SUPPORT STRUCTURE CORRODED FROM STA 1320 TO STA 1420 BETWEEN STR 28 AND STR 29. FABRICATED AND INSTALLED DOUBLER AND FILLER PER SRM 51 70 11 AND SRM 51 40 02. (X)