What was found
PHX - DURING SCHEDULED C7 INSPECTION, FOUND R1 DOOR STOP LUG CUTOUT CRACKED. ROUTED OUT CRACK AND INSTALLED REPAIR DOUBLER PER ER 3-52-10-10. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING SCHEDULED C7 INSPECTION, FOUND R1 DOOR STOP LUG CUTOUT CRACKED. ROUTED OUT CRACK AND INSTALLED REPAIR DOUBLER PER ER 3-52-10-10. (M)