What was found
PHX - DURING SCHEDULED C4 INSPECTION, FOUND R1 DOOR THRESHOLD ENTRY PLATE ATTACHMENT NUT PLATE HOLES CORRODED. INSTALLED REPLACEMENT THRESHOLD EXTRUSION PER SRM 51-72-00, PAGE 1 AND SRM 51-72-11, PAGE 1, 2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING SCHEDULED C4 INSPECTION, FOUND R1 DOOR THRESHOLD ENTRY PLATE ATTACHMENT NUT PLATE HOLES CORRODED. INSTALLED REPLACEMENT THRESHOLD EXTRUSION PER SRM 51-72-00, PAGE 1 AND SRM 51-72-11, PAGE 1, 2. (M)