What was found
PHX - DURING SCHEDULED C8 INSPECTION, FOUND R1 DOOR FORWARD GIRT BAR ATTACH FITTING CORRODED BEYOND LIMITS. FABRICATED REPLACEMENT FITTING AND INSTALLED PER SRM 51-30-2. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING SCHEDULED C8 INSPECTION, FOUND R1 DOOR FORWARD GIRT BAR ATTACH FITTING CORRODED BEYOND LIMITS. FABRICATED REPLACEMENT FITTING AND INSTALLED PER SRM 51-30-2. (M)