What was found
PHX - DURING SCHEDULED C4 INSPECTION, FOUND R1 DOOR HAT CHANNEL CORRODED BEYOND LIMITS FROM STATION 342 TO STATION 366. INSTALLED NEW FLOOR SUPPORT PER SRM 53-10-51, FIGURE 1. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING SCHEDULED C4 INSPECTION, FOUND R1 DOOR HAT CHANNEL CORRODED BEYOND LIMITS FROM STATION 342 TO STATION 366. INSTALLED NEW FLOOR SUPPORT PER SRM 53-10-51, FIGURE 1. (M)