What was found
PHX - DURING SCHEDULED C4 INSPECTION, FOUND AFT GALLEY FLOOR PAN CORRODED IN NUMEROUS AREAS FROM STATION 1681.8 THROUGH STATION 1740, RBL 2 THROUGH LBL 55. REPAIRED PER ER 5-53-16-11. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PHX - DURING SCHEDULED C4 INSPECTION, FOUND AFT GALLEY FLOOR PAN CORRODED IN NUMEROUS AREAS FROM STATION 1681.8 THROUGH STATION 1740, RBL 2 THROUGH LBL 55. REPAIRED PER ER 5-53-16-11. (M)