What was found
PHX - FLT NR 0020 - DURING ROUTINE MAINTENANCE CHECK, FOUND EMERENCY LIGHTS INOP AT R2 OVERHEAD AND AFT LAV CENTER AND RIGHT OVERHEAD. FOUND LOOSE CONNECTION AT POWER SUPPLY AFT OF L2 DOOR, OVERHEAD BIN NR 10 LEFT SIDE. RECONNECTED SYSTEM, OPS CHECKED GOOD. (M)