What was found
PAE - FLT NR 3839 - DURING SCHEDULED C-12 MAINTENANCE CHECK, FOUND STRINGER CRACKED AT BS 1115, WL 244, STRINGER 13R. REMOVED DAMAGED SECTION OF STRINGER 13R AND SECTION OF STIFFENER FOR ACCESS. FABRICATED REPAIR PARTS IAW SRM 53-10-03 AND ER NR 020696JMI. INSTALLED REPAIR PARTS FOR STRINGER AND INSTALLED STIFFENER IAW SRM'S 53-10-03, 51-40-02 AND ER NR 020696JMI. (M)