What was found
PAE - FLT 3861 - DURING ROUTINE SCHEDULED C-7 MAINTENANCE CHECK, FOUND CORROSION ON STATION 967 FLOOR BEAM, LBL 43 TO 49, WL 208. REMOVED CORROSION AREA FROM STATION 967, LBL 43 TO 49, WL 208 FLOOR BEAM, FABRICATED PART AND INSTALLED. ALODINED PER SRM 53-00-51, PAGE 207. (M)