What was found
FLT NR 3791 - PAE - DURING ROUTINE SCHEDULED C-4/S-1 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR SUPPORT RAIL X3259, 2 CM AFT OF FR 68, Y-1200, Z-540. REMOVED CORROSION ON FLOOR SUPPORT RAIL AT X3259, Y-1200, Z-540. FABRICATED PARTS FILLET RELIEF WASHERS, SPACERS ALODINED AND PRIMED, INSTALLED FASTENERS PER SRM 53-00-14. (M)