What was found
DURING ROUTINE SCHEDULED C-3 MX CHECK, FOUND CORROSION ON FLOORBEAM AT STATION 350, RBL 2-LBL 20, WL 208. REPAIR AREAS OF FLOORBEAM THAT ARE OUT OF LIMITS WITH REPAIR ANGLE AND FILLERS PER SRM 53-00-51. ALODINE, PRIME AND INSTALL WET WITH SEALANT. (M)