What was found
PAE - FLT 7809 - DURING ROUTINE SCHEDULED C-5 MAINTENANCE CHECK, FOUND CORROSION ON DUMMY RAIL Y=254, FR 21 THROUGH FR 16, Z -540. REMOVED, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 53-11-14. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PAE - FLT 7809 - DURING ROUTINE SCHEDULED C-5 MAINTENANCE CHECK, FOUND CORROSION ON DUMMY RAIL Y=254, FR 21 THROUGH FR 16, Z -540. REMOVED, FABRICATED AND INSTALLED REPAIR PARTS PER SRM 53-11-14. (M)