What was found
PAE - FLT 7806 - DURING ROUTINE SCHEDULED C-10 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM AROUND FLOOR HOLES LBL 21 AND LBL 28, STATION 344, WL 208. REPAIRED FLOOR BEAM STATION 344, LB 21 - 31.5, WL 208 PER SRM 53-10-51. (M)
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PAE - FLT 7806 - DURING ROUTINE SCHEDULED C-10 MAINTENANCE CHECK, FOUND CORROSION ON FLOOR BEAM AROUND FLOOR HOLES LBL 21 AND LBL 28, STATION 344, WL 208. REPAIRED FLOOR BEAM STATION 344, LB 21 - 31.5, WL 208 PER SRM 53-10-51. (M)