What was found
DURING ROUTINE MAINTENANCE CHECK, FOUND AFT FLOOR STRUCTURAL UPPER CAP AT THE I-BEAM STA 986 CORRODED BEYOND LIMITS. FABRICATED REPAIR SPLICES AND INSTALLED IAW SRM 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE MAINTENANCE CHECK, FOUND AFT FLOOR STRUCTURAL UPPER CAP AT THE I-BEAM STA 986 CORRODED BEYOND LIMITS. FABRICATED REPAIR SPLICES AND INSTALLED IAW SRM 51-40-02.