What was found
NR 2 ENGINE CANTILEVER STRUCTURE FROM RIB 01-07 OUTBOARD SPAR CRACKED. COMPLIED WITH AWA E.R. NR 32-54-20-15. TRANSFERRED TO AWM 106 NR 970009 FOR WEEKLY INSPECTION UNTIL PERMANENT REPAIR. S.IA. NR 54-002-97 ISSUED BY ENGINEERING ON 1-10-97. REQUIRES INSPECTING THE INBD AND OTBD EDGE SPAR ANGLES ON EACH PYLON IN THE AREA BETWEEN RIB 5 AND RIB 6 FOR CRACKS (DETAILED VISUAL INSPECTION) AT EVERY C-CHECK.