What was found
DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE OF FLOOR SUPPORT SIDE PANEL BS 1410 - 1530, LBL 20. REMOVED DAMAGED AREA OF FLOOR. FABRICATED AND INSTALLED SIDEWALL SUPPORT IAW, SRM 51-40-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE OF FLOOR SUPPORT SIDE PANEL BS 1410 - 1530, LBL 20. REMOVED DAMAGED AREA OF FLOOR. FABRICATED AND INSTALLED SIDEWALL SUPPORT IAW, SRM 51-40-2.