What was found
DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE OF FLOOR SUPPORT STRINGER BS 1328 - 1337, RBL 10. FABRICATED, ALODINED, PRIMED AND INSTALLED REPAIR PARTS PER SRM 51-70-12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON LOWER SURFACE OF FLOOR SUPPORT STRINGER BS 1328 - 1337, RBL 10. FABRICATED, ALODINED, PRIMED AND INSTALLED REPAIR PARTS PER SRM 51-70-12.