DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOOR SUPPORT STRINGER BS 1470, RBL 2. REMOVED DAMAGED FLOOR SUPPORT SECTION. FABRICATED AND INSTALLED NEW SUPPORT PER IAW, SRM 51-70-12.