What was found
DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON CARGO BAY FLOOR STRINGER BS 1564 TO 1570 RBL 2 WL 152. REMOVED, FABRICATED REPAIR PARTS AND INSTALLED PER SRM 51-70-12.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON CARGO BAY FLOOR STRINGER BS 1564 TO 1570 RBL 2 WL 152. REMOVED, FABRICATED REPAIR PARTS AND INSTALLED PER SRM 51-70-12.