What was found
DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOOR STRINGER AROUND NUTPLATES AT BS 1510, LBL 7, WL 156. REMOVED, FABRICATED REPAIR PARTS PER SRM 51-70-12 AND INSTALLED.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON FLOOR STRINGER AROUND NUTPLATES AT BS 1510, LBL 7, WL 156. REMOVED, FABRICATED REPAIR PARTS PER SRM 51-70-12 AND INSTALLED.