What was found
DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON STRINGER SPLICE AT BS 907, STR 17L. REMOVED CORRODED SECTION AND INSTALLED NEW STRINGER SPLICE IAW, SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE MAINTENANCE CHECK, FOUND CORROSION ON STRINGER SPLICE AT BS 907, STR 17L. REMOVED CORRODED SECTION AND INSTALLED NEW STRINGER SPLICE IAW, SRM 51-30-2.