What was found
DURING ROUTINE MAINTENANCE CHECK, FOUND RT I/B FLAP I/B END HAS CORROSION IN ONE OF THE CARRIAGE RETAINING BOLT HOLES. REMOVED AND REPLACED CORRODED PART PER CMM 57-33-4 AND SRM 51-30-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING ROUTINE MAINTENANCE CHECK, FOUND RT I/B FLAP I/B END HAS CORROSION IN ONE OF THE CARRIAGE RETAINING BOLT HOLES. REMOVED AND REPLACED CORRODED PART PER CMM 57-33-4 AND SRM 51-30-02.