What was found
DURING SCHEDULED C-11 INSPECTION, FOUND 10.5 BY 1. BY .025 DEEP DENT AT STATION 757 BETWEEN STRINGERS 10R AND 11R. CUT OUT DAMAGE IN A 5 BY 3.5 AREA, FABRICATED REPAIR DOUBLERS AND INSTALLED IAW, SRM 53-00-01 AT BS 750 TO 764, BETWEEN STRINGERS 10R AND 11R.