What was found
DURING SCHEDULED C-12 INSPECTION, FOUND SURFACE CORROSION ON FED CREASE BEAM WL 208, STA 327 TO 360. REMOVED AND REPLACED FORWARD ENTRY DOOR CREASE BEAM AT BS 277 TO 360, WL 208 IAW, SRM 53-30-13 AND 51-40-02.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
DURING SCHEDULED C-12 INSPECTION, FOUND SURFACE CORROSION ON FED CREASE BEAM WL 208, STA 327 TO 360. REMOVED AND REPLACED FORWARD ENTRY DOOR CREASE BEAM AT BS 277 TO 360, WL 208 IAW, SRM 53-30-13 AND 51-40-02.