What was found
DURING SCHEDULED C-23 INSPECTION, FOUND CORROSION ON I/B FLANGE, WL 208, O/B GALLEY TRACK STA 1000 TO 1006. REPLACED GALLEY TRACK IAW SRM 51-30-08, SRM 51-30-02.