What was found
DURING SCHEDULED C-6 INSPECTION, FOUND FLOOR SUPPORT CHANNEL AT NR 1 R CABIN SERVICE DOOR, BETWEEN BS 324 TO 365.25 RBL 62L, CORRODED WITH HOLES AND CORROSION ON TOP SURFACE (CHANNEL IS TWO PIECES). REMOVED AND REPLACED FLOOR SUPPORT CHANNELS PER SRM 51-10-00.