TESTED EMERGENCY EXIT LIGHTS IAW TASK CARD A1C33009, ROWS 20 THROUGH 23 LEFT SEAT MOUNTED LIGHTS DO NOT WORK. REPLACED POWER SUPPLY FUSE, OPS CHECK GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
TESTED EMERGENCY EXIT LIGHTS IAW TASK CARD A1C33009, ROWS 20 THROUGH 23 LEFT SEAT MOUNTED LIGHTS DO NOT WORK. REPLACED POWER SUPPLY FUSE, OPS CHECK GOOD.