What was found
IN MAINTENANCE FOUND CORRODED FLOORBEAM,STA 294.5 LBL 36 CORROSION. REMOVED DAMAGED AREA PER SRM 53-10-9 FIG 1. FABRICATED T CAP FROM BAC1505-100617 R642686 PER SRM 53-10-9 FIG 1 INSTALLED PER SRM 51-30-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
IN MAINTENANCE FOUND CORRODED FLOORBEAM,STA 294.5 LBL 36 CORROSION. REMOVED DAMAGED AREA PER SRM 53-10-9 FIG 1. FABRICATED T CAP FROM BAC1505-100617 R642686 PER SRM 53-10-9 FIG 1 INSTALLED PER SRM 51-30-2.