What was found
FORWARD PIT STATION 460 LT BETWEEN STR 20L AND 21L, INBOARD FRAME FLANGE HAS 3 CRACKS AT 3 RIVETS. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PARTS IAW SRM 51-40-3, FIGURE 1 AND SRM 53-10-2.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FORWARD PIT STATION 460 LT BETWEEN STR 20L AND 21L, INBOARD FRAME FLANGE HAS 3 CRACKS AT 3 RIVETS. REMOVED DAMAGED AREA, FABRICATED AND INSTALLED REPAIR PARTS IAW SRM 51-40-3, FIGURE 1 AND SRM 53-10-2.