What was found
AIR TURNBACK, AFTER RAISING THE GEAR ANNUNCIATOR INDICATED HYD PROBLEM 'A' SYS HYD. QUANTITY GAUGE WENT TO ZERO. FOUND NR 1 ENG T/R SHUTTLE VALVE FITTING BAD. REMOVED AND REPLACED FITTING.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
AIR TURNBACK, AFTER RAISING THE GEAR ANNUNCIATOR INDICATED HYD PROBLEM 'A' SYS HYD. QUANTITY GAUGE WENT TO ZERO. FOUND NR 1 ENG T/R SHUTTLE VALVE FITTING BAD. REMOVED AND REPLACED FITTING.