What was found
ACFT WAS INDUCTED INTO A 1 & 2 AND 5 A&B INSPECTION. DURING INSPECTION DISCOVERED THE LT MLG BRAKE ASSY HAD A CRACK IN ONE OF THE STATOR DISCS. BRAKE ASSY WAS RECEIVED FROM OUR PARTS DEPT HAD ABNORMAL WEAR ON THE WEAR PLATES & LININGS. BRAKE ASSY WAS REPAIRED AT AN OVERHAUL SHOP FOR A DAMAGED HOUSING. HOUSING WAS NOT STAMPED WITH S/B, THE FORM 8130 HAS NO RECORD OF LANDINGS/TIME IN SERVICE OF BRAKE ASSY OR A RECORD OF COMPLIANCE WITH BF GOODRICH S/B 2-1528-32-2, LANDING GEAR BRAKE ASSEMBLY POSSIBLE CRACKED STATOR DISKS.