What was found
DURING ROUTINE CPCP CHECK INSPECTION, FOUND STA 1060 R2 DOOR STR 14R AREA SKIN BULGING AND HEADLESS RIVETS. REMOVED CORROSION, AFTER ACCESSED AREA, IAW B727 SRM 51-10-6 FOUND TO BE OUT OF LIMITS IAW SRM 52-00-2. REPAIRED IAW SRM 51-40-3. CORROSION TASK CARD NUMBER C53-100-01. NON-ROUTINE TASK NUMBER 102863.