As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
DURING ROUTINE CPCP CHECK INSPECTION, FOUND STA 1030 TOP SIDE FLOORBEAM CORROSION WALL TO WALL. REPAIRED FLOORBEAM IAW AIA SKETCH NR AIA/E/2594 DATED 7-18-97, APPROVED BY FAA FORM 8110-3 DATED 7-21-97 PN=301 1/2HD 0.040IN AND FILLER 7075-T6. CORROSION TASK CARD NUMBER C53-111-01. NON-ROUTINE TASK CARD NUMBER 105803.