What was found
DURING ROUTINE CPCP CHECK INSPECTION, FOUND LT WING L/E AREA, NR 2 L/E FLAP STA 212 HAS SUPPORT ANGLE WEB CORRODED AND CORROSION AROUND ANCHOR NUTS. FOUND CORROSION TO BE OUT OF LIMITS IAW B727 SRM 57-20-1. REMOVED AND REPLACED ACCESS WEBBING PANEL, TOP COVER WEBBING, EXTRUSION PLATING BRACKET, AND O/B WEBBING BRACKET IAW B727 SRM 51-10-1, 51-30-2 AND MM 51-20-31 PN=2024-T3 PLATE, 7075-T6. CORROSION TASK CARD NUMBER C57-562-02. NON-ROUTINE TASK CARD NUMBER 110443.