What was found
DURING ROUTINE CPCP INSPECTION, FOUND FS 1030 LT SIDE CIRCUM HAS SMALL AREA OF CORROSION JUST UNDER FLOORBEAM. REMOVED CORROSION IAW SRM 51-10-6. ULTRASONIC THICKNESS CHECK MINIMUM NOMINAL: .045 MAX NOMINAL: .075. FOUND TO BE OUT OF LIMITS IAW B727 SRM 53-10-1. INSTALLED REPAIR IAW B727 SRM 51-40-3 FIG 1. CORROSION TASK CARD NUMBER C53-224-06. NON-ROUTINE TASK CARD NUMBER 11995.