What was found
DURING ACCOMPLISHMENT OF AD 92-12-03, FOUND STR 28L AT FS 950A HAS CORROSION FWD OF BEAM. REMOVED CORROSION IAW B727 SRM 51-10-1. ULTRASONIC THICKNESS CHECK, INTERGRANULAR CORROSION DETECTED REINSPECT U/T THICKNESS CK .116 NO FURTHER CORROSION NOTED. MADE AND INSTALLED REPAIR STRAP WITH FILLER IAW B727 SB 727-53-0179. NON-ROUTINE TASK CARD NUMBER 14823.