What was found
FACILITY FOR REPAIR - (HVY) - HD LO QTY - WHILE PERFORMING MX FOR HYD LEAK, FOUND LWR VS TE PANEL BOTTOM NUT PLATE BRACKET BROKEN OFF. VS TE LOWER CLOSURE RIB PN C01953501-005 AND VS TE HINGE #1 ASSY REPLACED PER CATA-55EA-02533.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
FACILITY FOR REPAIR - (HVY) - HD LO QTY - WHILE PERFORMING MX FOR HYD LEAK, FOUND LWR VS TE PANEL BOTTOM NUT PLATE BRACKET BROKEN OFF. VS TE LOWER CLOSURE RIB PN C01953501-005 AND VS TE HINGE #1 ASSY REPLACED PER CATA-55EA-02533.