SDR BB06067

Service difficulty report · Transmission · Boeing 7572B7

Difficulty date
August 25, 2006
Submitted
August 28, 2006
Operation
Air carrier
Aircraft
N624AU
Make and model
Boeing 7572B7
Aircraft serial
27245
Aircraft time
41,435 hours, 17,076 cycles
Part
Transmission
Part number
251N405047
Part serial
0085
Condition
Failed
Location
T/E Flap
Part time
32,858 hours, 13,009 cycles
Stage of operation
AP
How discovered
O
Nature of condition
F
Precautionary procedure
K

As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.

What was found

FLIGHT 1026, TPA-CLT: ON APPROACH, FLAPS FAILED TO MOVE. T/E LIMIT ILLUMINATED AND EICAS MESSAGE (T/E FLAP DISAGREE) AND (FLAP ISOL VAL) DISPLAYED. FLAPS OPERATE NORMAL USING T/E ALTERNATE SYSTEM. CREW DECLARED AN EMERGENCY. LANDED WITH NO FURTHER DIFFICULTIES. MAINTENANCE REPLACED THE LT FLAP TRANSMITTER, LT IB FLAP TRANSMISSION, AND RESET THE RT OB T/E FLAP OB TRANSMISSION.