As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FOUND TENSION TIE FITTING AT STA 104 STR 19L AND 20L CRACKED ON CORNER. LEVEL 2 CORROSION. REMOVED SECTION OF STATION 19L AT FS 104 FABRICATED REPAIR SECTION OF STATION AND TIE CLIP AT 19L AND 1104 TREATED, PRIMED AND INSTALLED STRINGER, SPLICES SECTION AND TIE CLIP IAW SRM.