What was found
DURING SCHEDULED C-CHECK INSPECTION DISCOVERED, L1 DOOR AFT GIRTH BAR ATTACH FITTING AND OUTBOARD FLOORBOARD SUPPORT AT BS 346 LBL 60 CORRODED. FOUND GIRTH BAR FITTING AND FLOORBOARD SUPPORT CORRODED OUT OF LIMITS FORMED REPAIR FLOORBOARD SUPPORT AND GIRTH BAR FITTING. INSTALLED IAW B737 SRM 51-40-3, FIG 1, 51-30-2, 51-10-2, 51-10-7, 51-30-8 AND 51-10-1. (M)