What was found
FOUND DENT/GOUGE 10.75IN AFT R1 DOOR AND 9.5 IN BELOW R1 DOOR FLOOR LINE AT WIDTH 0.5725IN AND LENGTH 0.279IN, DEPTH 0.044IN BETWEEN 2 RIVETS. BS 342.2. FOUND GOUGE ON RIVETE LINE 9.5IN BELOW FLOOR LINE R1 DOOR AND 11 IN AFT OF R1 DOOR LINE AT 0.8925IN AND 0.1750. BS 342. FOUND GOUGED DENT AT AREA 11.25 INCHES AFT R1 DOOR LINE AND 5 INCHES BELOW R1 DOOR LINE WITH DENT SIZE 0.578IN WIDTH AND 0.511 INCHES LENGTH WITH GOUGE DEPTH OF 0.023. BS 343.7. PERFORMED TEMPORY REPAIR IAW EA 53-24-36 REV 0. A/C OK FOR SERVICE.