What was found
NR 2 DC GENERATOR FAILED IN FLIGHT. AFTER THE ACFT RETURNED TO THE MX FACILITY, THE STARTER GENERATOR WAS REMOVED FOR INSPECTION. THE BRUSHES WERE FOUND WORN EXCESSIVELY AND BROKEN. REPLACED WITH AN O/H UNIT, ALL SYS CHECKED GOOD.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
NR 2 DC GENERATOR FAILED IN FLIGHT. AFTER THE ACFT RETURNED TO THE MX FACILITY, THE STARTER GENERATOR WAS REMOVED FOR INSPECTION. THE BRUSHES WERE FOUND WORN EXCESSIVELY AND BROKEN. REPLACED WITH AN O/H UNIT, ALL SYS CHECKED GOOD.