As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
FRAME DENTED IN FWD CARGO PIT OVER BS 680 OVER STRINGER 25R, MARKED. CUT OUT DAMAGED AREA 1.75 X .75 INCH AND FABBED REPAIR DOUBLER FROM 7075T6 .063 PO 9002351 DIM 9.75 X 3.75 INCH IAW 727 SRM 53-10-2 FIG 5 AND 51-40-3 FIG 1. REPAIR ANGLE TREATED AND PRIMED AND INSTALLED IAW 727 SRM 51-10-2 AND 51-40-3 FIG 1.