As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
What was found
RIGHT MLG WW LOAD APU CONTROL VALVE CUT OUT HOLE ON STA 870, WEB IS CRACKED. CRACK STOP DRILLED IAW 727 SRM 51-10-1. FABBED AND INSTALLED 2 EA DOUBLERS FROM 301 1/2 HD .050 PO 9912793 DIM 12 X 11 INCHES AND 18.5 X 21 INCHES IAW 727 SRM 53-10-9 FIG 5.