What was found
FRAME DENTED IN FWD CARGO -B- STA 660 OVER STRINGER 26R, MARKED. CUT OUT DAMAGED AREA DIM 2.125 X 1 INCH, FABBED REPAIR ANGLE FROM 7075T6 .063 PO 9002126 DIM 13 X 4 INCHES IAW 727 SRM 53-10-2 FIG 5 AND 51-40-3 FIG 1. REPAIR ANGLE TREATED AND PRIMED INSTALLED IAW 727 SRM 51-10-2 AND 51-40-3 FIG 1.