What was found
UPON APPLICATION OF FULL T/O THRUST NR 3 ENGINE POWER LEVER WENT TO FORWARD STOP AND EPR ONLY 2.00 (T/O EPR 2.09) T/O ABORTED IAW CHAMPION PROCEDURES. SOC, MX CONTROL NOTIFIED. ALL OTHER PARAMETERS IN YELLOW BAND FOR NR 3, NR 3 ENGINE INTAKE AND EXHAUST INSPECTED NO DAMAGE FOUND. PS4 & EPR (PT2/PT7) SENSITIVE LINES INSPECTED FOUND NORMAL. T/S PERFORMED IAW PWA JT8D MM 72-00-00 PAGE 151. LOWER THRUST ROD ADJUSTED IAW MM 76-12-00 PAGE 506. ENGINE POWER TEST PERFORMED ALL PARAMETERS NORMAL, REQUIRED T/O POWER MET.