What was found
PILLOWING AT FASTENERS BS 580 ABOVE STR 27L. CLEANED CORROSION ON SKIN WITH MATERIAL LOSS OF .008, ORIGINAL MATERIAL .063. FABRICATED SHEAR TIE FROM 1506-1388. REPAIRED AREA IAW B727 SRM 53-30-01 FIG 1, AND 53-10-2 FIG 3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
PILLOWING AT FASTENERS BS 580 ABOVE STR 27L. CLEANED CORROSION ON SKIN WITH MATERIAL LOSS OF .008, ORIGINAL MATERIAL .063. FABRICATED SHEAR TIE FROM 1506-1388. REPAIRED AREA IAW B727 SRM 53-30-01 FIG 1, AND 53-10-2 FIG 3.