What was found
CABIN FLOOR STRUCTURE BETWEEN BS 320-360 AT RBL 50, HAS SIDEWALL STIFFENER WITH CORROSION. REPLACED MAIN CABIN FLOOR ANGLE RBL 50 IAW B727 SRM 51-40-3.
As reported to the FAA. Reports are unverified, and codes are left as the FAA publishes them.
CABIN FLOOR STRUCTURE BETWEEN BS 320-360 AT RBL 50, HAS SIDEWALL STIFFENER WITH CORROSION. REPLACED MAIN CABIN FLOOR ANGLE RBL 50 IAW B727 SRM 51-40-3.