What was found
TYS. DURING HEAVY CHECK INSPECTION CORROSION WAS FOUND ON THE CENTER FLOOR BEAM AT FRAME 19A BETWEEN STRINGERS 21L AND 21R. MX REMOVED/REPLACED THE FLOOR BEAM IAW EMB-145 SRM 51-40-02.